Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS | |
Hu, Zhaochu1; Liu, Yongsheng1; Gao, Shan1; Liu, Wengui1; Zhang, Wen1; Tong, Xirun1; Lin, Lin1; Zong, Keqing1; Li, Ming1; Chen, Haihong1; Zhou, Lian1; Yang, Lu2 | |
2012 | |
发表期刊 | JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY |
卷号 | 27期号:9页码:1391-1399 |
摘要 | The effect of three different cone combinations on the performance of laser ablation MC-ICP-MS (Neptune plus) for the in situ Hf isotope analysis of zircon were investigated. The signal sensitivities of Hf, Yb and Lu were improved by a factor of 1.4 and 2.5, respectively, with using the X skimmer cone + standard sampler cone and the X skimmer cone + Jet sample cone compared to the standard arrangement (H skimmer cone + standard sample cone). However, when using the high-sensitivity Jet sample cone, the instrumental mass fractionation for hafnium displayed a large non-linear component that could not be corrected using the normal mass fractionation laws. The magnitude of this non-linear mass fractionation was strongly related to the central gas flow rate. The in situ Hf isotope analysis of zircon standards 91500 and Mud Tank using the Jet cone displayed large deviations (410-470 ppm) at the optimum central gas flow rate for Hf, which seriously deteriorated the performance of the Jet cone. The addition of 4 ml min(-1) nitrogen to the central gas flow in laser ablation MC-ICP-MS was found to not only increase the sensitivity of Hf by a factor of 2.1, but also suppress this non-linear mass fractionation. The determined Yb/Hf and Lu/Hf ratios at their corresponding optimum makeup gas flow rates for Hf intensity were found to be reduced by factors of 2 and 1.3 in the presence of nitrogen, respectively, which would benefit the accurate in situ determination of Hf isotopes in high-content Yb and Lu samples. Compared to the standard arrangement, the corresponding precision (2 sigma) of Hf-176/Hf-177 for single spot analysis of zircon standard 91500 was improved from 224 ppm to 50 ppm by using the newly designed X-skimmer cone and Jet sample cone in combination with the nitrogen addition technique. The determined Hf-176/Hf-177 ratios are in excellent agreement with published values in five reference zircon standards (91500, GJ-1, Mud Tank, Penglai and Plesovice). Our first Hf isotopic results from zircon standard M257 (0.281544 +/- 0.000018; 2SD, n = 151) showed that it was fairly homogeneous in Hf isotopes. These results clearly demonstrate that the present analytical method has the potential to become an important tool for the pursuit of high-quality in situ Hf isotope data for zircons. |
DOI | 10.1039/c2ja30078h |
语种 | 英语 |
ISSN | 0267-9477 |
收录类别 | SCI ; EI ; ESI高被引论文 |
EI入藏号 | 20123415356494 |
WOS记录号 | WOS:000307306600003 |
WOS类目 | Chemistry, Analytical ; Spectroscopy |
WOS研究方向 | Chemistry ; Spectroscopy |
出版者 | ROYAL SOC CHEMISTRY |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.cug.edu.cn/handle/2XU834YA/97237 |
专题 | 科研机构_地质过程与矿产资源国家重点实验室 教学院系_地球科学学院 行政部门_校长办公室 |
通讯作者 | Hu, Zhaochu |
作者单位 | 1.China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China 2.Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada |
推荐引用方式 GB/T 7714 | Hu, Zhaochu,Liu, Yongsheng,Gao, Shan,et al. Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS[J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,2012,27(9):1391-1399. |
APA | Hu, Zhaochu.,Liu, Yongsheng.,Gao, Shan.,Liu, Wengui.,Zhang, Wen.,...&Yang, Lu.(2012).Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,27(9),1391-1399. |
MLA | Hu, Zhaochu,et al."Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS".JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 27.9(2012):1391-1399. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Hu-2012-Improved in (938KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 请求全文 |