您好,欢迎访问中国地质大学(武汉)机构知识库!
图片搜索

   粘贴图片网址
Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS
Hu, Zhaochu1; Liu, Yongsheng1; Gao, Shan1; Liu, Wengui1; Zhang, Wen1; Tong, Xirun1; Lin, Lin1; Zong, Keqing1; Li, Ming1; Chen, Haihong1; Zhou, Lian1; Yang, Lu2
2012
发表期刊JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
卷号27期号:9页码:1391-1399
摘要The effect of three different cone combinations on the performance of laser ablation MC-ICP-MS (Neptune plus) for the in situ Hf isotope analysis of zircon were investigated. The signal sensitivities of Hf, Yb and Lu were improved by a factor of 1.4 and 2.5, respectively, with using the X skimmer cone + standard sampler cone and the X skimmer cone + Jet sample cone compared to the standard arrangement (H skimmer cone + standard sample cone). However, when using the high-sensitivity Jet sample cone, the instrumental mass fractionation for hafnium displayed a large non-linear component that could not be corrected using the normal mass fractionation laws. The magnitude of this non-linear mass fractionation was strongly related to the central gas flow rate. The in situ Hf isotope analysis of zircon standards 91500 and Mud Tank using the Jet cone displayed large deviations (410-470 ppm) at the optimum central gas flow rate for Hf, which seriously deteriorated the performance of the Jet cone. The addition of 4 ml min(-1) nitrogen to the central gas flow in laser ablation MC-ICP-MS was found to not only increase the sensitivity of Hf by a factor of 2.1, but also suppress this non-linear mass fractionation. The determined Yb/Hf and Lu/Hf ratios at their corresponding optimum makeup gas flow rates for Hf intensity were found to be reduced by factors of 2 and 1.3 in the presence of nitrogen, respectively, which would benefit the accurate in situ determination of Hf isotopes in high-content Yb and Lu samples. Compared to the standard arrangement, the corresponding precision (2 sigma) of Hf-176/Hf-177 for single spot analysis of zircon standard 91500 was improved from 224 ppm to 50 ppm by using the newly designed X-skimmer cone and Jet sample cone in combination with the nitrogen addition technique. The determined Hf-176/Hf-177 ratios are in excellent agreement with published values in five reference zircon standards (91500, GJ-1, Mud Tank, Penglai and Plesovice). Our first Hf isotopic results from zircon standard M257 (0.281544 +/- 0.000018; 2SD, n = 151) showed that it was fairly homogeneous in Hf isotopes. These results clearly demonstrate that the present analytical method has the potential to become an important tool for the pursuit of high-quality in situ Hf isotope data for zircons.
DOI10.1039/c2ja30078h
语种英语
ISSN0267-9477
收录类别SCI ; EI ; ESI高被引论文
EI入藏号20123415356494
WOS记录号WOS:000307306600003
WOS类目Chemistry, Analytical ; Spectroscopy
WOS研究方向Chemistry ; Spectroscopy
出版者ROYAL SOC CHEMISTRY
引用统计
被引频次:871[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.cug.edu.cn/handle/2XU834YA/97237
专题科研机构_地质过程与矿产资源国家重点实验室
教学院系_地球科学学院
行政部门_校长办公室
通讯作者Hu, Zhaochu
作者单位1.China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
2.Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
推荐引用方式
GB/T 7714
Hu, Zhaochu,Liu, Yongsheng,Gao, Shan,et al. Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS[J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,2012,27(9):1391-1399.
APA Hu, Zhaochu.,Liu, Yongsheng.,Gao, Shan.,Liu, Wengui.,Zhang, Wen.,...&Yang, Lu.(2012).Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,27(9),1391-1399.
MLA Hu, Zhaochu,et al."Improved in situ Hf isotope ratio analysis of zircon using newly designed X skimmer cone and jet sample cone in combination with the addition of nitrogen by laser ablation multiple collector ICP-MS".JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 27.9(2012):1391-1399.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Hu-2012-Improved in (938KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Hu, Zhaochu]的文章
[Liu, Yongsheng]的文章
[Gao, Shan]的文章
百度学术
百度学术中相似的文章
[Hu, Zhaochu]的文章
[Liu, Yongsheng]的文章
[Gao, Shan]的文章
必应学术
必应学术中相似的文章
[Hu, Zhaochu]的文章
[Liu, Yongsheng]的文章
[Gao, Shan]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Hu-2012-Improved in situ Hf isotope ratio anal.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。